source: buchla-68k/orig/DOC/SEQDISP.TXT@ a838f5b

Last change on this file since a838f5b was 3ae31e9, checked in by Thomas Lopatic <thomas@…>, 7 years ago

Imported original source code.

  • Property mode set to 100755
File size: 5.3 KB
Line 
1Sequencer Extensions to MIDAS-VII Rev 3 1988-11-07
2--------------------------------- ----- ----------
3
4Sequence Display Format
5-----------------------
6
7 0 1 2 3 4 5 6
8 012345678901234567890123456789012345678901234567890123456789012
900 (===============================================!=============) 00
1001 | Lin Time_ Action_1___ Action_2___ Action_3___ | No Seq RG T | 01
1102 | | 01 999 99 0 | 02
1203 | | 02 999 99 0 | 03
1304 | | 03 999 99 0 | 04
1405 | | 04 999 99 0 | 05
1506 | | 05 999 99 0 | 06
1607 | | 06 999 99 0 | 07
1708 | | 07 999 99 0 | 08
1809 | 999 12.45 Ks 128 1 01 If R01=?3 Jump to 000 < 08 999 99 0 | 09
1910 | | 09 999 99 0 | 10
2011 | | 10 999 99 0 | 11
2112 | | 11 999 99 0 | 12
2213 | | 12 999 99 0 | 13
2314 | | 13 999 99 0 | 14
2415 | | 14 999 99 0 | 15
2516 | | 15 999 99 0 | 16
2617 | | 16 999 99 0 | 17
2718 [===============================================*=============] 18
2819 | Key transient Trigger on Stop Set reg Value | 19
2920 | Key closure Trigger off Jump to lin If reg = Register | 20
3021 | Key release Trig toggle If reg < Voltage | 21
3122 | If key active If trig act If stim act If reg > Random | 22
3223 | | 23
3324 {=============================================================} 24
34 0 1 2 3 4 5 6
35 012345678901234567890123456789012345678901234567890123456789012
36
37Special characters used above:
38------------------------------
39
40 ( \272 ! \267 ) \273 vg \275\276
41 [ \266 * \265 ] \264 < \274
42 { \271 = \261 } \270 | \260
43
44Area Object Usage Top Left Bottom Right Width
45---- ------ ------- --- ---- ------ ----- -----
46 0 obj8 heading 0 0 1 63 64 *
47 1 obj9 sequences 2 0 17 47 48
48 2 obj10 status 2 48 17 63 16 *
49 3 obj11 menu 18 0 24 63 64 *
50
51 * Note: The last character position in area 0, 2, or 3 is unused.
52
53
54Kt nnn n nn Key transient
55Kc nnn n nn Key closure
56Kr nnn n nn Key relase
57If nnn n nn If key active
58
59Trig on nn Trigger on
60Trig off nn Trigger off
61Trig tgl nn Trigger toggle
62If Trig nn If trigger active
63
64Set Rnn=Rnn Set register to register contents
65Set Rnn=nn Set register to constant value
66Set Rnn=Vn Set register to voltage input
67Set Rnn=?n Set register to random value
68
69If Rnn=Rnn Compare register -- equal to register contents
70If Rnn=nn Compare register -- equal to constant value
71If Rnn=Vn Compare register -- equal to voltage input
72If Rnn=?n Compare register -- equal to random value
73
74If Rnn<Rnn Compare register -- less than register contents
75If Rnn<nn Compare register -- less than constant value
76If Rnn<Vn Compare register -- less than voltage input
77If Rnn<?n Compare register -- less than random value
78
79If Rnn>Rnn Compare register -- greater than register contents
80If Rnn>nn Compare register -- greater than constant value
81If Rnn>Vn Compare register -- greater than voltage input
82If Rnn>?n Compare register -- greater than random value
83
84If Stim act Test sequence stimulus active
85
86Jump to nnn Jump to sequence line
87
88Stop Stop sequence
89
90
91Submenu columns and widths
92--------------------------
93
94 Left Right Width
95 ---- ----- -----
96 2 14 13
97 17 27 11
98 30 40 11
99 43 50 8
100 53 60 8
101
102
103Submenu boxes
104-------------
105
106 1 Key transient 5 Trigger on 9 Stop 13 Set reg 17 Value
107 2 Key closure 6 Trigger off 10 Jump to lin 14 If reg = 18 Register
108 3 Key release 7 Trig toggle 11 --unused-- 15 If reg < 19 Voltage
109 4 If key active 8 If trig act 12 If stim act 16 If reg > 20 Random
110
111
112ST_0 -- Initial action submenu
113------------------------------
114
115 0 1 2 3 4 5 6
116 012345678901234567890123456789012345678901234567890123456789012
11719 | Key transient Trigger on Stop Set reg | 19
11820 | Key closure Trigger off Jump to lin If reg = | 20
11921 | Key release Trig toggle If reg < | 21
12022 | If key active If trig act If stim act If reg > | 22
121
122
123
124ST_1 -- Register action submenu
125-------------------------------
126
127 0 1 2 3 4 5 6
128 012345678901234567890123456789012345678901234567890123456789012
12919 | Value | 19
13020 | Register | 20
13121 | Voltage | 21
13222 | Random | 22
133
Note: See TracBrowser for help on using the repository browser.